Home » Products » Dry Type Transformer » Low Voltage Dry Type Transformer » Low voltage Dry Type Transformers

loading

loading

Low voltage Dry Type Transformers

Availability:

Product Description

Dry Type Vacuum Cast Resin Transformer Specifications:


· Capcity:30kVA-2500kVA
· Usage:Power ransformer,distribution transformer
· Structure: Epoxy casting type
· Regulating Range:±5/±2×2.5
· The Level of Partial Discharge:≤10
· Transport Package:Export Wooden Box
· Cooling Method:AN/AF
· Certification:ISO9001
· Core Materia:Silicon Steel
· Rated Frequency:50Hz/60Hz
· Grade of Insulation for Heat Resistance:Grade F or Above


Dry Type Vacuum Cast Resin Transformer Applications:


· Chemical, oil, and gas industry

· Environmentally sensitive areas (e.g. water protection areas)

· Fire-risk areas (e.g. forests)

· Inner-city substations

· Indoor and underground substations

· Renewable generation (e.g. off-shore wind turbines )

Applications


Dry Type Vacuum Cast Resin Transformer Advantage:



· Sourceway's cast-resin transformers offer maximum mechanical strength to withstand thermal and mechanicalstresses from severe climates, cycling loads, and short circuit forces.

· Sourceway's transformer windings arehermetically cast in epoxy without the use of a mold for maximum design flexibility.

· Sourceway’s transformersare non-exp osive with high resistance to flame and do not reguire vaults, containment dikes, or costlv firesuppression systems.

· Sourceway's transformers are produced in full compliance with ISO 9001 and ISO 14001 standards.


· Modern winding processes, combined with electronically controlled winding machinery, ensure an evendistribution of glass fibre rovings and epoxy resin, and the highest precision in the manufacture of transformerwindings. Multi-spaced ribs, built-in during the winding process, integrate the HV and LV windings into a singlecompact winding block. No risk of any contamination to the application environment and non-explosive withhigh resistance to flame.

· Severe load cycles (cold start to maximum load) and high short circuit withstand.Exposure to harsh climates (freezing, heat, chemicals, moisture): minimal maintenance.


· The iron core:

· The core is made of high quality cold-rolled grain oriented silicon steel sheet with mineral oxide insulation

· By controlling the cutting and stacking process of silicon steel sheet, the loss level, no-load current and noise can be minimized

· The surface of the assembled core is sealed with grade F or grade H core paint to prevent dust and corrosion


· HV winding:

· has a firm structure during normal operation and transportation

· The low voltage winding is made of high quality copper foil - The insulation between layers is made of thermosetting epoxy prepreg cloth - The ends of the windings are insulated with thermosetting epoxy prepreg cloth - Excellent insulation resistance · It has very good ability to bear radial stress caused by short circuit - The outlet terminal of low voltage winding is tin-plated copper bar

· whole winding is placed in the oven and heated to 140°C. After 4 hours of polymerization, it has excellent corrosion resistance to industrial gases


· LV winding:

· is placed in the oven and heated to 140°C. After 4 hours of polymerization, it has excellent corrosion resistance to industrial gases

· Woven with insulated copper wire, and applied by hengfengyou electric exclusive patent technology - For small volumes, the high voltage winding uses a linear voltage gradient from top to bottom - For large-capacity products, the high-voltage windings are wound by "band winding" technology - The application of these methods causes the electric field between adjacent conductors to be very low - The transformer has a firm structure during normal operation and transportation


Dry Type Vacuum Cast Resin TransformerStandard Fittings:


· Terminal Connectors

· Cast resin coils

· Epoxy Resin Capacitive Insulator

· Special Termination Arrangement

· Cable Box / Bus Duct

· Cooling Fan

· Rollers (Uni-Directional / Bi-Directional) Protection with Temperature Scanner

· Scanner Off Circuit Tap Changer


Dry Type Vacuum Cast Resin Transformer Transport Packaging:


· Single-phase transformers are packaged in three ways: wooden pallets, wooden frames, and wooden boxes.

· We generally use wooden box packaging, which can effectively protect the transformer during transportation

· Avoid collisions and keep the shape of the transformer intact

· Avoid corrosion, rust, etc. caused by environmental factors


linkedin sharing button
whatsapp sharing button
facebook sharing button
twitter sharing button
pinterest sharing button
line sharing button
wechat sharing button
sharethis sharing button

Related Products

Inquiry
Established in 2006
Social Media
Product Category
Power Transformer
Contact Info
 Phone: +86 18057699597
 WhatsApp: +86 18057699597
WeChat: +86 18057699597
 Add: No.1 Xinggong 8 Rd., Jiangshan, Zhejiang, China
Contact Us
Copyright @ 2023 Zhejiang SourceWay Electric Co., Ltd. All Rights Reserved  Sitemap | Support  By Leadong | Privacy Policy